R Value to K Value Converter: Simple Formula

Formulas & functions · Updated November 23, 2026

The direct conversion is: R-value (ft²·°F·hr/Btu) = K-value (Btu·in/ft²·hr·°F) × thickness (inches). To convert a K-value to an R-value, divide the thickness by the K-value; to go from R-value to K-value, divide the thickness by the R-value. For example, a 2-inch thick material with a K-value of 0.25 has an R-value of 2 / 0.25 = 8.

What R-Value and K-Value Actually Measure

R-value (thermal resistance) measures how well a material resists heat flow. Higher R-values mean better insulation. It is the standard metric used in building codes, insulation product labels, and energy calculations in the US and Canada. R-value is always tied to a specific thickness—a 1-inch board and a 2-inch board of the same material have different R-values.

K-value (thermal conductivity) measures how well a material conducts heat per unit thickness. It is a material property, independent of thickness. Lower K-values mean better insulation. K-value is typically expressed in Btu·in/(ft²·hr·°F) in imperial units, or W/(m·K) in metric. The key distinction: K-value describes the material itself; R-value describes a specific piece of that material at a given thickness.

The Exact Conversion Formula (Imperial Units)

In US customary units, the relationship is straightforward:

  • R = thickness (inches) ÷ K (where K is in Btu·in/ft²·hr·°F)
  • K = thickness (inches) ÷ R (same units)

Example: A 3.5-inch fiberglass batt has a K-value of 0.29. Its R-value is 3.5 / 0.29 = 12.07, usually rounded to R-13. Conversely, if you need an R-value of 20 and the material has a K-value of 0.4, the required thickness is R × K = 20 × 0.4 = 8 inches.

For metric K-values (W/m·K), the conversion requires unit changes. First convert K from W/m·K to Btu·in/ft²·hr·°F by multiplying by 6.933. Then use the same formula with thickness in inches. Or use metric R-value (m²·K/W) directly: R_metric = thickness (meters) ÷ K_metric.

Why You Can’t Convert Without Thickness

A common mistake is trying to convert a K-value to an R-value without specifying thickness. K-value is a per-inch property; R-value is a total property. For example, a K-value of 0.5 could describe a 1-inch board with R=2, or a 4-inch board with R=8. The conversion only works when you know the exact thickness of the material you are using.

If you see a label that says “R-value per inch,” that is actually the reciprocal of the K-value (1/K). For instance, a material with K=0.25 has an R-value per inch of 4.0. Many insulation manufacturers list both K-value and R-value per inch to avoid confusion.

Common Unit Systems and Conversions

You will encounter two main unit systems:

  • Imperial (US): K in Btu·in/(ft²·hr·°F), R in ft²·°F·hr/Btu. Thickness in inches.
  • Metric (SI): K in W/(m·K), R in m²·K/W. Thickness in meters.

To convert between them:

  • 1 W/(m·K) = 6.933 Btu·in/(ft²·hr·°F)
  • 1 m²·K/W = 5.678 ft²·°F·hr/Btu

Example: A rigid foam board has a K-value of 0.024 W/(m·K). In imperial units, that is 0.024 × 6.933 = 0.166 Btu·in/ft²·hr·°F. For a 2-inch thickness, R = 2 / 0.166 = 12.05 ft²·°F·hr/Btu. In metric, R = 0.0508 m / 0.024 = 2.12 m²·K/W.

How to Use This in Real Life (Spreadsheet Formula)

If you are working in Excel, you can set up a simple converter. Assume cell A1 contains the K-value (imperial, Btu·in/ft²·hr·°F) and cell B1 contains the thickness in inches. In cell C1, enter:

=B1/A1

That returns the R-value. For metric K (W/m·K) with thickness in meters, use:

=B1/A1

But if you have imperial thickness and metric K, first convert K to imperial in a helper cell. For example, with K_metric in A1 and thickness in inches in B1:

=B1/(A1*6.933)

For the reverse (R to K), with R in A1 and thickness in inches in B1:

=B1/A1

Always double-check your units—mixing inches and meters is the most common error.

Choosing Between R-Value and K-Value

When comparing insulation products, use R-value for total performance at a given thickness. Use K-value when comparing materials of different thicknesses or when designing a layered assembly. For example, a 1-inch sheet of polyiso foam (K=0.20) has R=5.0, while a 2-inch sheet of EPS (K=0.25) has R=8.0. The polyiso is a better insulator per inch, but the EPS provides more total resistance at 2 inches.

Building codes typically specify minimum R-values for walls, roofs, and floors. To meet those, you calculate required thickness using the K-value of your chosen material. Always check the manufacturer’s data sheet for the exact K-value, as it varies with density, temperature, and aging.

Common Mistakes and Misconceptions

  • Confusing R-value per inch with total R-value: A label saying “R-5 per inch” means 1 inch gives R-5, 2 inches gives R-10.
  • Using metric K with imperial thickness: This leads to wildly wrong numbers. Always convert units first.
  • Assuming K-value is constant: K changes with temperature and moisture. Most published values are at 75°F (24°C) and dry conditions.
  • Adding R-values of different materials without considering thermal bridging: The simple addition works only for continuous layers.

Frequently Asked Questions

What is the difference between R-value and U-value?

U-value (thermal transmittance) is the reciprocal of R-value (U = 1/R). It measures heat flow through an assembly, including air films and framing. Lower U-values are better. While R-value is used for insulation materials, U-value is used for whole assemblies like windows or walls.

Can I convert R-value to K-value without knowing thickness?

No. K-value is per unit thickness, so you must know the thickness to calculate R-value. If you see an R-value on a product, it is already thickness-specific. To get K, divide the thickness by the R-value.

Is a higher R-value always better?

Yes, for insulation, higher R-value means better thermal resistance. However, there are diminishing returns and practical limits—adding more insulation costs more and may not be worth it beyond code requirements. Also, R-value does not account for air leaks or thermal bridging.

How do I convert K-value in W/m·K to R-value in ft²·°F·hr/Btu?

First multiply the K-value by 6.933 to get Btu·in/ft²·hr·°F. Then divide the thickness in inches by that number. For example, K=0.035 W/m·K becomes 0.2427 Btu·in/ft²·hr·°F. For 4 inches, R = 4 / 0.2427 = 16.5.

Why do some insulation products list both K and R values?

Manufacturers list both because engineers and builders use different metrics. K-value helps compare materials of different thicknesses, while R-value is what building codes and energy calculations use. Listing both avoids confusion for different audiences.

Does R-value change with temperature?

Yes, slightly. Most insulation materials have a K-value that varies with temperature, so R-value also changes. The published values are usually at 75°F mean temperature. At very cold or hot temperatures, the actual performance may differ by a few percent, which is usually negligible for building design.