The direct conversion is: R-value (ft²·°F·hr/Btu) = K-value (Btu·in/ft²·hr·°F) × thickness (inches). To convert a K-value to an R-value, divide the thickness by the K-value; to go from R-value to K-value, divide the thickness by the R-value. For example, a 2-inch thick material with a K-value of 0.25 has an R-value of 2 / 0.25 = 8.
What R-Value and K-Value Actually Measure
R-value (thermal resistance) measures how well a material resists heat flow. Higher R-values mean better insulation. It is the standard metric used in building codes, insulation product labels, and energy calculations in the US and Canada. R-value is always tied to a specific thickness—a 1-inch board and a 2-inch board of the same material have different R-values.
K-value (thermal conductivity) measures how well a material conducts heat per unit thickness. It is a material property, independent of thickness. Lower K-values mean better insulation. K-value is typically expressed in Btu·in/(ft²·hr·°F) in imperial units, or W/(m·K) in metric. The key distinction: K-value describes the material itself; R-value describes a specific piece of that material at a given thickness.
The Exact Conversion Formula (Imperial Units)
In US customary units, the relationship is straightforward:
- R = thickness (inches) ÷ K (where K is in Btu·in/ft²·hr·°F)
- K = thickness (inches) ÷ R (same units)
Example: A 3.5-inch fiberglass batt has a K-value of 0.29. Its R-value is 3.5 / 0.29 = 12.07, usually rounded to R-13. Conversely, if you need an R-value of 20 and the material has a K-value of 0.4, the required thickness is R × K = 20 × 0.4 = 8 inches.
For metric K-values (W/m·K), the conversion requires unit changes. First convert K from W/m·K to Btu·in/ft²·hr·°F by multiplying by 6.933. Then use the same formula with thickness in inches. Or use metric R-value (m²·K/W) directly: R_metric = thickness (meters) ÷ K_metric.
Why You Can’t Convert Without Thickness
A common mistake is trying to convert a K-value to an R-value without specifying thickness. K-value is a per-inch property; R-value is a total property. For example, a K-value of 0.5 could describe a 1-inch board with R=2, or a 4-inch board with R=8. The conversion only works when you know the exact thickness of the material you are using.
If you see a label that says “R-value per inch,” that is actually the reciprocal of the K-value (1/K). For instance, a material with K=0.25 has an R-value per inch of 4.0. Many insulation manufacturers list both K-value and R-value per inch to avoid confusion.
Common Unit Systems and Conversions
You will encounter two main unit systems:
- Imperial (US): K in Btu·in/(ft²·hr·°F), R in ft²·°F·hr/Btu. Thickness in inches.
- Metric (SI): K in W/(m·K), R in m²·K/W. Thickness in meters.
To convert between them:
- 1 W/(m·K) = 6.933 Btu·in/(ft²·hr·°F)
- 1 m²·K/W = 5.678 ft²·°F·hr/Btu
Example: A rigid foam board has a K-value of 0.024 W/(m·K). In imperial units, that is 0.024 × 6.933 = 0.166 Btu·in/ft²·hr·°F. For a 2-inch thickness, R = 2 / 0.166 = 12.05 ft²·°F·hr/Btu. In metric, R = 0.0508 m / 0.024 = 2.12 m²·K/W.
How to Use This in Real Life (Spreadsheet Formula)
If you are working in Excel, you can set up a simple converter. Assume cell A1 contains the K-value (imperial, Btu·in/ft²·hr·°F) and cell B1 contains the thickness in inches. In cell C1, enter:
=B1/A1
That returns the R-value. For metric K (W/m·K) with thickness in meters, use:
=B1/A1
But if you have imperial thickness and metric K, first convert K to imperial in a helper cell. For example, with K_metric in A1 and thickness in inches in B1:
=B1/(A1*6.933)
For the reverse (R to K), with R in A1 and thickness in inches in B1:
=B1/A1
Always double-check your units—mixing inches and meters is the most common error.
Choosing Between R-Value and K-Value
When comparing insulation products, use R-value for total performance at a given thickness. Use K-value when comparing materials of different thicknesses or when designing a layered assembly. For example, a 1-inch sheet of polyiso foam (K=0.20) has R=5.0, while a 2-inch sheet of EPS (K=0.25) has R=8.0. The polyiso is a better insulator per inch, but the EPS provides more total resistance at 2 inches.
Building codes typically specify minimum R-values for walls, roofs, and floors. To meet those, you calculate required thickness using the K-value of your chosen material. Always check the manufacturer’s data sheet for the exact K-value, as it varies with density, temperature, and aging.
Common Mistakes and Misconceptions
- Confusing R-value per inch with total R-value: A label saying “R-5 per inch” means 1 inch gives R-5, 2 inches gives R-10.
- Using metric K with imperial thickness: This leads to wildly wrong numbers. Always convert units first.
- Assuming K-value is constant: K changes with temperature and moisture. Most published values are at 75°F (24°C) and dry conditions.
- Adding R-values of different materials without considering thermal bridging: The simple addition works only for continuous layers.
Frequently Asked Questions
What is the difference between R-value and U-value?
U-value (thermal transmittance) is the reciprocal of R-value (U = 1/R). It measures heat flow through an assembly, including air films and framing. Lower U-values are better. While R-value is used for insulation materials, U-value is used for whole assemblies like windows or walls.
Can I convert R-value to K-value without knowing thickness?
No. K-value is per unit thickness, so you must know the thickness to calculate R-value. If you see an R-value on a product, it is already thickness-specific. To get K, divide the thickness by the R-value.
Is a higher R-value always better?
Yes, for insulation, higher R-value means better thermal resistance. However, there are diminishing returns and practical limits—adding more insulation costs more and may not be worth it beyond code requirements. Also, R-value does not account for air leaks or thermal bridging.
How do I convert K-value in W/m·K to R-value in ft²·°F·hr/Btu?
First multiply the K-value by 6.933 to get Btu·in/ft²·hr·°F. Then divide the thickness in inches by that number. For example, K=0.035 W/m·K becomes 0.2427 Btu·in/ft²·hr·°F. For 4 inches, R = 4 / 0.2427 = 16.5.
Why do some insulation products list both K and R values?
Manufacturers list both because engineers and builders use different metrics. K-value helps compare materials of different thicknesses, while R-value is what building codes and energy calculations use. Listing both avoids confusion for different audiences.
Does R-value change with temperature?
Yes, slightly. Most insulation materials have a K-value that varies with temperature, so R-value also changes. The published values are usually at 75°F mean temperature. At very cold or hot temperatures, the actual performance may differ by a few percent, which is usually negligible for building design.
Related
- Number to String in C++: 4 Ways to Convert
- Cell Counting Chamber: How to Use & Choose
- SQL Split: How to Split Strings in SQL Queries
Try it: the Formula Explainer: paste any formula and see each function and reference in plain English.
More in Formulas & functions
- How to Round Numbers in Excel to the Nearest ThousandIf the value is in A2, enter =ROUND(A2,-3) to round it to the nearest thousand; for example, 1,234,567…
- Excel Filter Not Showing All Data? Find the Cause FastExcel filters usually miss rows because the filter range stops before the full dataset, or because the values…
- How to Filter Two Columns in ExcelTo filter two columns in Excel, turn on AutoFilter for your data, then choose a filter in the…
- Excel Formula for Every Friday Date in a Date Range ListWith a start date in A2 and an end date in B2, this Microsoft 365 formula returns every…
- Excel Date Minus Date in Years? DATEDIF ExplainedThe direct answer: use =DATEDIF(start_date, end_date, "Y") to get whole years between two dates in Excel. For example,…
- Remove Duplicates in Excel: Sort Data the Right WayTo remove duplicates in Excel and keep the right record, sort your data first if the order determines…
Sources: Function behaviour and menu paths: Microsoft Support documentation for Excel. Method & sources
Spotted an error in this guide? Let us know.